AccelBuilding Company: Build to Last.
Phone: 201.535.4685
Email: info@AccelBuilding.com
Home About Us Buildings up to 4 stories Buildings 4+ stories Custom Homes Bangalos / Garages

  Architect Benefits
  Builder Benefits
  Tradesmen Benefits
  Occupant Benefits
  Your Project Flow
  Technical Data
  Our Partners
  FAQ

Technical Data

Panel at a glance
 
Some Architectural Specifications
  Wall Panel A-1 Wall Panel B-1 Wall Panel C-1 Wall Panel D-1
Thickness 3 ½’’ 3 ½’’ 5 ½ ‘’ 5 ½ ‘’
EPS Density 1.5 PCF 1.5 PCF 1.0 PCF 1.0 PCF
Steel Studs @ 16’’O.C @ 24’’O.C @ 16’’O.C @ 24’’O.C
Length 8’ to 12’ 8’ to 12’ 8’ to 12’ 8’ to 12’
UL Flame Spread Rating 5-101 5-101 5-201 5-201
UL Smoke Developed Rating 65-3001 65-3001 125-1751 125-1751
Total Panel Weight (8’/12’) (lb) 49.00 / 71.00 42.00 / 60.00 50.00 / 73.00 43.00 / 61.00
Dead Load (8’/12’)(plf) 12.00 / 18.00 10.00 / 16.00 12.00 / 18.00 10.00 / 16.00
Allowable Axial Uniform Loading (8’/12’) (plf) 1195 / 1120

12402

915 / 795

10002

1265 / 1230

18692

910 / 970

13002

Allowable Axial Center Point Loading (8’/12’) (lb) 595 / -

26472

585 / -

24372

630 / 890

30102

590 / 735
Allowable Transverse Loading (8’/12’) (psf) 25 / 10

26.72

20 / 5

19.52

40 / 15

40.32

30 / 10
Allowable Racking Shear (plf) 165

8712 / 15733

70

8312 / 11463

125

12483

65

6402

To request additional technical information, email info@AccelBuilding.com or call 201.535.4685